XIONG Cen DU Chuanhua CHEN Quanyou LI Heyi ZHAO Hongchao. Study of the total ionization dose and Transient Dose rate effects of a Toggle magnetoresistive random access memory[J/OL]. Nuclear techniques, 2026, 49.
DOI:
XIONG Cen DU Chuanhua CHEN Quanyou LI Heyi ZHAO Hongchao. Study of the total ionization dose and Transient Dose rate effects of a Toggle magnetoresistive random access memory[J/OL]. Nuclear techniques, 2026, 49. DOI:
Study of the total ionization dose and Transient Dose rate effects of a Toggle magnetoresistive random access memory
摘要
Abstract
[Background] Magnetoresistive random access memory (MRAM) has the advantages of non-volatility
fast speed
low power consumption
high endurance
and long data retention
which make it a potential candidate forapplication in aerospace electronic systems. [Purpose] This study aims to examine the total ionization dose(TID) and transient dose rate (TDR) effects of a Toggle MRAM. [Methods] A remote on-line test system was designed for in-situ measurement of the radiation effect of the MRAM. The TID and TDR response of MRAM were studied experimentally in various working modes. [Results]The following results are obtained: 1) During TID experiment
the early response of the MRAMs is an increase of the supply current. Bit errors occur at a total dose of 30 krad(Si). 2) During the TDR experiment
neither data nor function errors was observed in static power-on mode and dynamic read mode
whereas data write failure occurred in dynamic write mode. Reason for the write failure may bethat the global photocurrent of the circuit caused a fluctuation in the power supply
which triggered the write protection of the device and hindered the following data writing process. [Conclusions] Results from the experiments indicate that MRAM exhibits malfunctions under total dose and transient ionizing radiation environments. The radiation sensitive and vulnerable part of the MRAM is its peripheral circuits.